List of Equipment and Measuring Instruments within EMC Laboratory
Since 1997, the EMC tests
have begun to be accredited by Romanian Accreditation Association- RENAR
(member of ILAC and EA) according to EN 17025.
In 2000 it was put into operation the semi-anechoic chamber, the first of
this kind in Romania.
|
Immunity Tests |
|
Standard |
Tests |
Description |
Technical Data |
Scope |
|
ELECTROSTATIC DISCHARGES |
||||
|
EN 61000 - 4 - 2 IEC 61000 - 4 - 2
|
|
Electrostatic |
8 kV (contact) 15 kV (air) |
Immunity of equipment subjected to static electricity discharges from operators directly or to adjacent objects |
|
ACCREDITED BY RENAR |
||||
|
RADIATED DISTURBANCES |
||||
|
EN 61000 - 4 - 3 IEC 61000 - 4 - 3 |
|
Radiated electromagnetic energy |
10 V / m |
Immunity of equipment subjected to radio-frequency electromagnetic fields |
|
ACCREDITED BY RENAR |
||||
|
CONDUCTED DISTURBANCES |
||||
|
EN 61000 - 4 - 4 IEC 61000 - 4 - 4
|
|
Electrical fast transient / burst |
4 kV max. |
Immunity at transient disturbances, such as those originating from switching transients (interruption of inductive loads, relay contact bounce, etc.) |
|
ACCREDITED BY RENAR |
||||
|
EN 61000 - 4 - 5 IEC 61000 - 4 - 5
|
|
Surge immunity tests |
4.5 kV/2.25 kA |
Immunity to unidirectional surges caused by over-voltages from switching and lightning transients |
|
ACCREDITED BY RENAR |
||||
|
EN 61000 - 4 - 6 IEC 61000 - 4 - 6
|
|
Conducted disturbances, induced by radio-electric fields |
80 Veff
|
Immunity at conducted disturbances, induced by radio-electric fields, coming from intended RF trans-mitters |
|
ACCREDITED BY RENAR |
||||
|
EN 61000 - 4 - 8 IEC 61000 - 4 - 8 EN 61000 - 4 - 9 IEC 61000 - 4 - 9 |
|
Power frequency and pulse magnetic fields |
50 Hz |
Immunity at power frequency and pulse magnetic fields, generated by coils |
|
ACCREDITED BY RENAR |
||||
|
EN 61000 - 4 - 11 IEC 61000 - 4 - 11 |
|
Voltage dips, short interruptions and voltage variations |
0 - 100 % UN 10000 ms |
Immunity at voltage dips, short interruptions and voltage variations for electric equipment not exceeding 16 A / phase |
|
ACCREDITED
BY RENAR
|
||||
|
EN 61000 - 4 - 12 IEC 61000 - 4 - 12 |
|
Oscilatory waves |
- 100kHz/4kV -0,1 and 1MHz/ 2,5kV |
Immunity at oscillatory waves for electrical and electronic equipment |
|
In
progress
|
||||
|
Emission Measurements |
| Standard |
Tests |
Description |
Technical Data |
Scope |
| CONDUCTED DISTURBANCES |
||||
|
EN 55011 CISPR 11 - IEC |
|
Electromagnetic disturbances at radio-frequency |
0,15 - 30 MHz |
Measurement of radio-frequency disturbances for industrial, scientific and medical equipment |
| ACCREDITED BY RENAR |
||||
|
EN 55014 CISPR 14 - IEC
|
|
Electromagnetic disturbances at radio-frequency |
0,15 - 30 MHz |
Measurement of radio-frequency disturbances for motor operated and thermal appliances for household and similar purposes, electric tools, etc. |
| ACCREDITED BY RENAR |
||||
|
EN 55015 CISPR 15 - IEC
|
|
Electromagnetic disturbances at radio-frequency |
0,15 - 30 MHz |
Measurement of radio-frequency disturbances for electrical lighting and similar equipment |
| ACCREDITED BY RENAR |
||||
|
EN 55022 CISPR 22 - IEC |
|
Electromagnetic disturbances at radio-frequency |
0,15 - 30 MHz |
Measurement of radio-frequency disturbances for information technology equipment |
| ACCREDITED BY RENAR |
||||
|
EN 55014-1 CISPR 14-1- IEC |
|
Discontinous disturbances (clicks) |
148,5 kHz - 30 MHz |
Measurement of discontinous disturbances forhousehold and similar equipment |
| ACCREDITED BY RENAR |
||||
| EN 55015 CISPR 15-IEC |
Insertion
loss |
150
kHz - 1605 kHz |
Measurement of insertion loss for electrical lighting and similar equipment | |
| ACCREDITED
BY RENAR |
||||
|
EN 55017 CISPR 17-IEC |
Insertion
loss |
10
kHz - 1000 MHz |
Measurement of insertion loss of passive radio interference filters | |
| ACCREDITED
BY RENAR |
||||
| EN 61000 - 3 - 2 IEC 61000 - 3 - 2 |
![]() |
Harmonics
current emmissions |
100
Hz - 2 kHz (n=2 - 40) |
Measurement of Harmonics Emmisions for non-professional equipment up to 16A/phase |
| ACCREDITED
BY RENAR |
||||
| EN 61000 - 3 - 3 IEC 61000 - 3 - 3 |
![]() |
Voltage
fluctuations and flicker emmissions |
-Short-term
flicker Pst -Long-term flicker Plt -Relative voltage charge dc -Maximum voltage charge dmax |
Measurement of voltage fluctuations and flicker for electronic equipment up to 16A/phase |
| ACCREDITED BY RENAR |
||||
| RADIATED DISTURBANCES |
||||
|
EN 55011 CISPR 11 - IEC |
|
Electromagnetic disturbances at radio-frequency |
0,15 - 1000 MHz |
Measurement of electromagnetic disturbances for industrial, scientific and medical equipment |
| In progress |
||||
|
EN 55014-1 CISPR 14 - 1 - IEC
|
|
Electromagnetic disturbances at radio-frequency |
30 - 300 MHz |
Measurement of electromagnetic disturbance for motor - operated and thermal appliances for household and similar purposes, electric tools etc (disturbance power) |
| ACCREDITED BY RENAR |
||||
|
EN 55015 CISPR 15 - IEC
|
![]() |
Measurements
in three directions of magnetic field components |
0,09 - 30 MHz |
Measurement of electromagnetic disturbance for electrical lighting and similar equipment |
| ACCREDITED BY RENAR |
||||
|
EN 55022 CISPR 22 - IEC
|
|
Electromagnetic disturbances at radio-frequency |
30 - 1000 MHz |
Measurement of electromagnetic disturbances for information technology equipment |
| In progress |
||||
|
List of Equipment and Measuring Instruments within EMC Laboratory |
| Semi
Anechoic Chamber |
10
V/m |
| Measuring
Screened Chamber |
> 80 dB Shielding Effectiveness |
| Screened
Room 5725 x 2350 x 2625 mm |
>
120 dB Shielding Effectiveness |
| Helmholtz Coils System | 2,450mT |
| Electromagnetic
Interference Receiver |
9 kHz - 2.6 GHz |
| Artificial
Network |
9 kHz - 30 MHz |
| Absorbing
Clamp |
30 MHz - 1 GHz |
| Electric
Field Meter |
100 kHz - 3GHz |
| Three-phase
Artificial Mains Network Type LT 32/C |
9kHz
- 30MHz |
| Magnetic
Field Analyser |
5 Hz - 30 kHz |
| Broadband
Hybrid Antenna |
20 MHz - 1 GHz |
| Signal
Generator |
9 kHz – 2.08 GHz |
| Power
Meter |
DC - 26.5 GHz |
| Thermal
Power Sensor |
DC - 18 GHz |
| Dual
Directional Coupler |
100 kHz - 1 GHz |
| Power
Amplifier |
80 MHz - 1 GHz |
| Combination
Wave Generator |
50 - 4500 V |
| Electrical
Fast Transient Generator |
200 - 4400 V |
| Electrostatic
Discharge Simulator |
0 - 15 kV |
| Voltage
Interruption Simulator |
0 - 280 V |
| Generator/Amplifier/RFVoltmeter
Type CDG 6000 |
100
kHz-266MHz |
| Transfer
Field Strength Meter with µ-TEM Cell Type TFS 11 |
10
MHz-1 GHz |
| Electromagnetic
Field Meter Type EnviroMentor |
0-1000 V/m 0,05-100 µT |
| Digital
Oscilloscope
|
500 MHz |
| Absorbing
Clamp Type F-201 |
300
MHz-1000 MHz |
| Click
analyzer Type CL 55C |
150
kHz, 500 kHz, 1.4MHz, 30 MHz |
| Loop
Antenna Type TLA300 |
9
kHz-30 MHz |
Passive
Probe |
9
kHz-30 MHz |
| Spectrum
Analyzer Type FSH 3 |
100
kHz-3 GHz |
| Digital
Multimeter Type Keithley 2000 |
100
mV-1000 V |
| Field
Generator Type Ref Rad 3000 |
1
MHz-3 GHz |
| Flicker
& Harmonics Analyzer Type HAR 100-1P |
50
Hz-2 kHz |
| Near
Field Sniffer Probes |
0,1 MHz – 1 GHz |
Send mail to market@icmet.ro
with questions or comments about this web site.
Copyright © 2003 Research-Development and Testing National Institute
for Electrical Engeneering